Sign In | Join Free | My components-electronic.com |
|
Brand Name : sangsolar
Model Number : MPS0150-240S
Certification : EN 62109-1/-2
MOQ : Pallet
Price : Negotiated
Payment Terms : TT/LC/Alibabashop
Supply Ability : 2GW/Year
Delivery Time : 10-30days
Packaging Details : Carton on Pallet
Max. Power (kVA) : 165 kVA
Rated Power (kW) : 150 kW
Rated Current (A) : 361A
Max. PV Voltage : 1,000V
Voltage Range : 420-850V
Dimensions (W×D×H) : 1,200×800×2,050 mm
This 150kW hybrid inverter delivers industrial-grade three-phase power with split-phase flexibility, specifically engineered for large-scale microgrids and energy-intensive facilities. Featuring up to four MPPT trackers and 420-850V battery integration, it achieves 98.5% peak efficiency while supporting parallel configurations for megawatt-scale deployments.
50% Higher Power Output - 150kW continuous (165kVA peak) for heavy industrial loads
Enhanced Solar Capacity - Up to 240kW PV input for larger solar arrays
Advanced Thermal Management - Optimized cooling system for 24/7 operation
240V high-leg delta with split-phase output
*Technical note: Proprietary phase-balancing algorithm maintains <1% voltage imbalance while simultaneously delivering three-phase 240V and 120V single-phase power.*
192-276V wide input range
*Technical note: DSP-controlled voltage regulation with ±1% accuracy and <20ms response to grid disturbances.*
2-4 MPPT trackers (120-240kW capacity)
Technical note: Independent maximum power point tracking per channel reduces mismatch losses by 35% in partially shaded arrays.
1,000V DC input with 250-850V MPPT range
*Technical note: Cold-start capability at 150V with 1,200V surge protection for harsh environments.*
420-850V battery voltage range
Technical note: Integrated battery health monitoring tracks impedance changes (±2% accuracy) for predictive maintenance.
240kW max charging power
*Technical note: Adaptive 4-stage charging (bulk/absorption/float/equalization) with temperature compensation.*
-30°C cold-start with 55°C continuous operation
*Technical note: Military-grade components rated for 100,000+ hours MTBF in extreme conditions.*
IP20 enclosure (IP65 optional)
Technical note: Corrosion-resistant coating on all external components for coastal installations.
(Refer to Section 2 for complete specifications table)
Steel mill arc furnaces
*Technical note: Handles 200% short-term overloads during electrode strikes with <3% voltage dip.*
Aluminum smelting operations
Technical note: Maintains stable power quality for potline operations.
Microgrid primary control
*Technical note: 16-unit parallel support with <5ms synchronization for seamless load sharing.*
Peaker plant replacement
Technical note: 500ms black start capability for grid resilience.
Data center backup systems
Technical note: <20ms transition time meets Tier IV uptime requirements.
Q: How does this compare to using multiple 100kW units?
*A: Reduces balance-of-system costs by 30% with centralized control while providing 33% more MPPT channels for complex solar fields.*
Q: What SCADA protocols are supported?
A: Native support for DNP3, IEC 61850, and Modbus TCP for utility integration.
Q: Can it island during grid failures?
*A: Yes, with <20ms transition time and 51/81 protection relay emulation.*
⚠ Electrical
600A minimum disconnect
3/0 AWG copper conductors (90°C rating)
Dedicated neutral-ground bond
⚠ Structural
1,500kg floor load capacity
1m service clearance
Category | Specifications |
---|---|
AC Output (On-Grid) | |
Max. Power (kVA) | 165 kVA |
Rated Power (kW) | 150 kW |
Voltage Configuration | 240V High-Leg Delta with Split Phase |
Voltage Range | 192-276V |
Rated Current (A) | 361A |
Frequency | 50/60 Hz (±5 Hz adjustable) |
THDi | <3% |
Power Factor | Adjustable (0.8 leading/lagging) |
AC Output (Off-Grid) | |
THDu | <1% (linear), <5% (nonlinear) |
Overload Capacity | 110% continuous |
PV Input | |
Max. PV Voltage | 1,000V |
Max. PV Power | 120/180/240 kW |
MPPT Trackers | 2/3/4 |
MPPT Voltage Range | 250-850V |
Battery | |
Voltage Range | 420-850V |
Max. Charging Power | 120/180/240 kW |
Physical Data | |
Dimensions (W×D×H) | 1,200×800×2,050 mm |
Weight | 1,250-1,310 kg |
Operating Temperature | -30°C to 55°C |
Protection Rating | IP20 |
Noise Level | <70 dB |
Communication | RS485, CAN, TCP/IP |
![]() |
150kW 240V High-Leg Delta Hybrid Inverter with Quad MPPT and Split-Phase Output for Industrial Microgrids Images |